Abstract:

At the Kielce University of Technology a novel method for in situ cylindricity measurement has been developed. It has been called a V-block method and its fundamental is using a set of two connected V-blocks. Along the element connecting V-blocks the measuring sensor moves. The method is characterized by so-called detectability coefficient that is responsible for detection of the harmonic components in observed profile. The value of the coefficient depends on the angular method parameters, i.e. V-blocks angle and the position of the sensor. The paper presents fundamentals of the V-block method and results of the research work on influence angular method parameters on measurement results.



B   I   B   L   I   O   G   R   A   F   I   A
[1] ZHAO W. Q., XUE Z., TAN J. B., WANG Z. B.: SSEST: A new approach to higher accuracy cylindricity measuring instrument, International Journal of Machine Tools and Manufacture, 46(2006) 14, 1869-1878.
[2] OSANNA P. H., DURAKBASA, N. M., CAKMAKCI M., OBERLÄNDER, R.: Cylindricity – a well known problem and solution,
International Journal of Machine Tools and Manufacture, 32 (1992) 1-2, 91-97.
[3] DAWSON D.J.W.: Cylindricity and its measurement, International Journal of Machine Tools and Manufacture, 32 (1992) 1-2, 247-253.
[4] KAKINO Y., KITAZAWA J.: In situ measurement of cylindricity, Annals of the CIRP,27 (1978) 1, 371-375.
[5] OKUYAMA E., GOHO K., MITSUI K.: New analytical method for V-block three-point method, Precision Engineering, 27 (2003) 3, 234-244.
[6] SONOZAKI S., FUJIWARA H.: Simultaneous measurement of cylindrical parts profile and rotating accuracy using multi-three-point- method, Bulletin of Japan Society of Precision Engineering, 23 (1989) 4, 286-291.
[7] MURALIKRISHNAN B., VENKATACHALAM S., RAJA J., MALBURG M.: A note on the three-point method for roundness measurement, Precision Engineering, 29 (2005) 2, 257-260.
[8] ADAMCZAK S. et al: Concept of reference methods for accurate measurements of roundness of machine elements (in Polish). Science report KBN no. 7T07D04008, Kielce University of Technology, Kielce, 1997.
[9] KATSURADA K., GOHO K., MITSUI K., HAYASHI A.: Cylindricity measurement of parallel rollers based on a V-block method, Nippon Kikai Gakkai Ronbunshu, CHen/Transactions of the JSME, 69 (2003) 11, 3124-3129.
[10] ISO/DIS 12180-1, 2: 1999, Geometrical Product Specifications (GPS) – Cylindricity.
[11] MAO J., CAO Y., YANG J.: Implementation uncertainty evaluation of cylindricity errors based on geometrical product specification (GPS), Measurement, 42 (2009) 5, 742-747.
[12] MUDRONJA V., MAHOVICI S., RUNJE B.: Determining the difference between estimated and realised measurement uncertainty based on comparative measurements, Strojarstvo, 46 (2004) 4-6, 115-124.
[13] HLOCH S., VALIČEK J., SAMARDŽIĆ I., KOZAK D., MULLEROVA J., GOMBAR M.: Experimental study of surface topography created by abrasive waterjet cutting, Strojarstvo, 49 (2007) 4, 303-309.
[14] SADILEK M., ČEP R., BUDAK I., SOKOVIĆ M.: Aspects of using tool axis inclination angle, Strojniski Vestnik-Journal of Mechanical Engineering, 57 (2011) 9, 681-688.
[15] HLAVÁČEK P., VALIČEK J., HLOCH S., GREGER M., FOLDYNA J., IVANDIĆ Ž., SITEK S., KUŠNEROVA M., ZELENAK M., Measurement of fine grain copper surface texture created by abrasive water jet cutting, Strojarstvo, 51 (2009) 4, 273-279.
[16] ČEP R., NESLUŠAN M., BARIŠIĆ B.: Chip formation analysis during hard turning, Strojarstvo, 50 (2008) 6, 337-346.
[17] NYBERG, T.R.: Dynamic macro topography of large slowly rotating cylinders, Acta Polytechnica Scandinavica, Mechanical Engineering Series No. 108, Helsinki, 1993.
[18] EHMANN K. F., LIN, C.: In-process measurement of roundness and cylindricity, American Society of Mechanical Engineers, Production Engineering Division (Publication) PED, 55 (1991), 59-71.
[19] PONIATOWSKA M.: Parameters for CMM contact measurements of free-form surfaces. Metrology and Measurement Systems, 18 (2011) 2, 199-207.
[20] ZAWADA-TOMKIEWICZ A.: Classifying the wear of turning tools with neural networks, Journal of Materials Processing Technology, 109 (2001) 3, 300-304.
[21] BOERDIJK A.H.: Controle van de Rondheid, De Ingenieur, 64 (1954), 29-30.
[22] CANFIELD W.: And must be round, Machinist 102 (1958) 25, 109-120.
[23] REASON R.E.: Report on the measurement of roundness, Rank Taylor Hobson Limited, Leicester 1966.
[24] WITZKE F.W.: In-situ out-of-roundness measurement, Proceedings of the Institution of Mechanical Engineers, 182(1968) 3, 430-437.
[25] WHITEHOUSE D.J.: Some theoretical aspects of error separation techniques in surface metrology, Journal of Physics E: Scientific Instruments, 9 (1976), 531-536.
[26] ADAMCZAK S., JANECKI, D., STĘPIEŃ, K.: Concept of reference measurements of cylindricity profiles of machine parts, XVII IMEKO World Congress - Proceedings, Dubrovnik, 2003, pp. 201.
[27] JANECKI D., STĘPIEŃ K.: Applying the normalized cross correlation function to the comparison of cylindricity profiles. Metrology and Measurement Systems, 9 (2004) 3, 209 – 220.
[28] JANECKI D., STĘPIEŃ, K.: A study of the effects of the sensor guideway slope on the results of the reference measurement of cylindricity deviations, Measurement Automation and Monitoring - Pomiary Automatyka Kontrola, 5 (2008), 258–262.
[29] ADAMCZAK S., JANECKI D., STĘPIEŃ, K.: An analysis of errors of V-block cylindricity measurement with a regard to the method parameters, XVIII IMEKO World Congress, Metrology for a Sustainable Development - Proceedings, Rio de Janeiro, Brazil, 2006.
[30] ADAMCZAK S., JANECKI D., STĘPIEŃ, K.: Qualitative and quantitative evaluation of the accuracy of the V-block method of cylindricity measurements, Precision Engineering, 34 (2010) 3, 619-626.
[31] STĘPIEŃ K., JANECKI D., ADAMCZAK, S.: Investigating the influence of selected factors on results of V-block cylindricity measurements, Measurement, 44 (2011) 4, 767-777.
[32] ADAMCZAK S., JANECKI D., STĘPIEŃ, K.: Cylindricity measurement by the V-block method – Theoretical and practical problems, Measurement, 44 (2011) 1, 164-173.