[136880] Artykuł: TOMOGRAPHIC TESTING OF ALNICO ALLOYSCzasopismo: Proceedings 31st International Conference on Metallurgy and Materials Strony: 675-681ISSN: 2694-9296 Opublikowano: Listopad 2022 Autorzy / Redaktorzy / Twórcy Grupa MNiSW: Pozostałe publikacje (niepunktowane) Punkty MNiSW: 0 ![]() ![]() Keywords: Non destructive testing  X-ray testing  computer tomographic testing  alnico alloys  |
We follow an alnico alloy sample to non destructive testing using X-ray radiography. X-ray Computed Tomography (CT), also widely known as MicroCT, is a proven method for not only checking the structural integrity of casting parts - for example for porosity - but also for checking a dimensional accuracy. It is important for assessment casting with complex or small internal areas that could not be inspected by conventional measurements without failure of the final products. Moreover, we were able to visualize the internal defects of the different shapes of casting objects. The gray-value contrasts of the CT images were excellent to distinguish the resin material in the alloy samples. This will be a useful qualitative and quantitative advancement to rapid and detailed non-destructive analysis within the die-casting industries in improving the quality of the alnico alloys.