Notice: Undefined index: linkPowrot in C:\wwwroot\wwwroot\publikacje\publikacje.php on line 1275
Publikacje
Pomoc (F2)
[126960] Artykuł:

A Two-dimensional Numerical Model of Heat Exchange in the Soil Massif During the Operation of a Shallow Horizontal Soil Heat Exchanger

Czasopismo: Rocznik Ochrona Środowiska   Tom: 25, Strony: 274-281
ISSN:  1506-218X
Opublikowano: 2023
Liczba arkuszy wydawniczych:  1.00
 
  Autorzy / Redaktorzy / Twórcy
Imię i nazwisko Wydział Katedra Do oświadczenia
nr 3
Grupa
przynależności
Dyscyplina
naukowa
Procent
udziału
Liczba
punktów
do oceny pracownika
Liczba
punktów wg
kryteriów ewaluacji
Borys Basok Niespoza "N" jednostkiInżynieria środowiska, górnictwo i energetyka20.00.00  
Anatoliy Pavlenko orcid logo WiŚGiEKatedra Fizyki Budowli i Energii Odnawialnej*Takzaliczony do "N"Inżynieria środowiska, górnictwo i energetyka2070.0031.30  
Oleksandr Nedbailo Niespoza "N" jednostkiInżynieria środowiska, górnictwo i energetyka20.00.00  
Ihor Bozhko Niespoza "N" jednostkiInżynieria środowiska, górnictwo i energetyka20.00.00  
Maryna Moroz Niespoza "N" jednostkiInżynieria środowiska, górnictwo i energetyka20.00.00  

Grupa MNiSW:  Publikacja w czasopismach wymienionych w wykazie ministra MNiSzW (część A)
Punkty MNiSW: 70


Pełny tekstPełny tekst     DOI LogoDOI    
Słowa kluczowe:

shallow horizontal soil heat exchanger  heat flux  numerical modelling  renewable energy sources 


Keywords:

shallow horizontal soil heat exchanger  heat flux  numerical modelling  renewable energy sources 



Streszczenie:

The current article uses a two-dimensional numerical model to represent the results of theoretical studies of the heat exchange in the soil massif during the operation of a shallow horizontal soil heat exchanger. The analysis of literature sources showed that one of the important conditions for the effective operation of a shallow-soil heat exchange is its rational design parameters, such as the total length of the pipeline, the diameter of the pipe, the distance between the axis of the adjacent pipes, the depth of the heat exchanger placement, etc. A two-dimensional heat exchange model in the soil mass was developed, which made it possible to investigate the operation of a shallow horizontal soil heat exchanger. It was found that the step between the axis of the adjacent pipes of the multi-loop heat exchanger, which is 0.95 m, is optimal when creating a shallow horizontal soil heat exchanger in the soil conditions of Kyiv.




Abstract:

The current article uses a two-dimensional numerical model to represent the results of theoretical studies of the heat exchange in the soil massif during the operation of a shallow horizontal soil heat exchanger. The analysis of literature sources showed that one of the important conditions for the effective operation of a shallow-soil heat exchange is its rational design parameters, such as the total length of the pipeline, the diameter of the pipe, the distance between the axis of the adjacent pipes, the depth of the heat exchanger placement, etc. A two-dimensional heat exchange model in the soil mass was developed, which made it possible to investigate the operation of a shallow horizontal soil heat exchanger. It was found that the step between the axis of the adjacent pipes of the multi-loop heat exchanger, which is 0.95 m, is optimal when creating a shallow horizontal soil heat exchanger in the soil conditions of Kyiv.