[99670] Artykuł:

Analysis of the Possibility of Using the Plain CFD Model to Simulate Two-Phase Flows in Spatial Systems of Pressure Sewer Networks

Czasopismo: WATER   Tom: 12, Zeszyt: 6, Strony: 1-14
ISSN:  2073-4441
Opublikowano: Czerwiec 2020
Liczba arkuszy wydawniczych:  1.00
 
  Autorzy / Redaktorzy / Twórcy
Imię i nazwisko Wydział Katedra Do oświadczenia
nr 3
Grupa
przynależności
Dyscyplina
naukowa
Procent
udziału
Liczba
punktów
do oceny pracownika
Liczba
punktów wg
kryteriów ewaluacji
Piotr Siwicki Niespoza "N" jednostki20.00.00  
Marcin Krukowski Niespoza "N" jednostki20.00.00  
Jan Studziński Niespoza "N" jednostki20.00.00  
Bartosz Szeląg orcid logo WiŚGiEKatedra Geotechniki, Geomatyki i Gospodarki Odpadami*Niezaliczony do "N"Inżynieria środowiska, górnictwo i energetyka20100.00100.00  
Rafał Wojciechowski Niespoza "N" jednostki20.00.00  

Grupa MNiSW:  Publikacja w czasopismach wymienionych w wykazie ministra MNiSzW (część A)
Punkty MNiSW: 100


Pełny tekstPełny tekst     DOI LogoDOI    
Keywords:

pressure sewer installations  siphons  laboratory tests  CFD modeling  volume of fluid VOF method 



Abstract:

The paper analyzes the possibility of using the CFD (Computational Fluid Dynamics) method to predict the amount of sewage remaining in siphons after a full air blast of the pressure sewer system. For this purpose, the results from measurements carried out on a laboratory installation were compared with the results obtained from modelling using a spatial model (3D) and a plain model (2D) of the installation. To determine these models, the structure of the VOF (Volume of Fluid) model was used in the CFD method. The simulation calculations carried out make it possible to state that the use of the plain model with the development of the installation modelled in the plan does not result in significant deterioration of the obtained results. The possibility of using 2D models for modelling pumped sewer systems allows for a significant shortening of the calculation time, which, in practice, results in the possibility of modelling much larger and longer installations than is possible with 3D models.