Notice: Undefined index: linkPowrot in C:\wwwroot\wwwroot\publikacje\publikacje.php on line 1275
[48474] Artykuł: Static and dynamic analysis of a pump impeller with a balancing device. Part II: Dynamic analysisCzasopismo: International Journal of Applied Mechanics and Engineering Tom: 19, Zeszyt: 3, Strony: 621-631ISSN: 1425-1655 Opublikowano: 2014 Autorzy / Redaktorzy / Twórcy
Grupa MNiSW: Publikacja w recenzowanym czasopiśmie wymienionym w wykazie ministra MNiSzW (część B) Punkty MNiSW: 7 DOI YADDA/CEON Słowa kluczowe: pompa wirowa  wirnik  analiza dynamiczna  Keywords: dynamic analysis  pump impeller  balance device  stability condition  |
This paper presents the theoretical study of the system comprising an impeller and a balancing device. It deals with the dynamic analysis of the system, i.e., the axial vibrations of the impeller, and the system stability. The dynamic analysis took into account linearized hydrodynamic forces and moments generated in the longitudinal clearances of the seals of the impeller. The theoretical analysis was supplemented with a numerical example with characteristics determined for a real single-stage centrifugal pump.