Notice: Undefined index: linkPowrot in C:\wwwroot\wwwroot\publikacje\publikacje.php on line 1275
Publikacje
Pomoc (F2)
[42090] Artykuł:

Quasi-stationary phase change heat transfer on a fin

Czasopismo: The European Physical Journal Web of Conferences   Tom: 114, Zeszyt: 02086, Strony: 1-5
ISSN:  2100-014X
Wydawca:  E D P SCIENCES, 17 AVE DU HOGGAR PARC D ACTIVITES COUTABOEUF BP 112, F-91944 CEDEX A, FRANCE
Opublikowano: 2016
Seria wydawnicza:  EPJ Web of Conferences
 
  Autorzy / Redaktorzy / Twórcy
Imię i nazwisko Wydział Katedra Procent
udziału
Liczba
punktów
Tadeusz Orzechowski orcid logoWiŚGiEKatedra Sieci i Instalacji Sanitarnych507.50  
Katarzyna Stokowiec orcid logoWiŚGiEKatedra Sieci i Instalacji Sanitarnych507.50  

Grupa MNiSW:  Materiały z konferencji międzynarodowej (zarejestrowane w Web of Science)
Punkty MNiSW: 15
Klasyfikacja Web of Science: Proceedings Paper


Pełny tekstPełny tekst     DOI LogoDOI     Web of Science Logo Web of Science    
Keywords:

phase change  paraffin. quasi-stationary  heat transfer coefficient 



Abstract:

The paper presents heat transfer research basing on a long fin with a circular cross-section. Its basis is welded to the pipe where the hot liquid paraffin, having a temperature of 70oC at the inflow, is pumped. The analyzed element is a recurrent part of a refrigeration’s condenser, which is immersed in
a paraffin. The temperature of the inflowing liquid is higher than the temperature of the melting process for paraffin, which allows the paraffin to liquify. The temperature at the basis of the rib changes and it is assumed that the heat transfer is quasi-stationary. On this basis the estimation of the mean value of heat transfer coefficient was conducted. The unsteady thermal field of the investigated system was registered with an infrared camera V50 produced by a Polish company Vigo System. This device is equipped with a microbolometric detector with 384 × 288 elements and the single pixel size
25 × 25 μm. Their thermal resolution is lower than 70 mK at a temperature of 30 oC. The camera operates at 7,5 ÷ 14 µm long-wave infrared radiation range. For a typical lens 35 mm the special resolution is 0.7 mrad. The result of the calculations is mean heat transfer coefficient for the considered time series. It is equal to 50 W m -2 K-1 and 47 W m -2 K-1 on the left and right side of the fin, respectively. The distance between the experimental data and the curve approximating the temperature distribution was assessed with the standard deviation, Sd = 0.04 K.